40W Single Output |
|
AP-40-5 |
|
AP-40-12 |
|
AP-40-15 |
|
AP-40-24 |
|
|
|
FEATURES |
|
Low-cost, high reliability |
|
High efficiency, low working temp. |
|
Built in EMI filter, low ripple noise |
|
Compact size, light weight |
|
100% full load burn-in test |
|
Short circuit/over load protection |
|
Type No | Output | Tol. | R & N | Effi. | CK-40-5 | 5V, 8A | ±2 | 75mV | 72% | CK-40-12 | 12V, 3.5A | ±1 | 100mV | 76% | CK-40-15 | 15V, 2.8A | ±1 | 100mV | 76% | CK-40-24 | 24V, 1.8A | ±1 | 100mV | 78% | Input voltage | 85~264VAC full range | Input frequency | 47~63Hz | Inrush current | Cold start, 25A/115V, 50A/230V | Output voltage | Refer to above (±10% ADJ.) | Overload protection | 105% ~ 150% output pulsing mode | Over voltage protection | 115% ~ 135% output voltage | Setup, rise, hold up time | 800ms, 50ms, 15ms/115VAC | | 300ms, 50ms, 80ms/230VAC | Withstand voltage | I/P-O/P: 3KV, 1/P-FG: 1.5KV, 1 min. | Working temp | 0~50°C@100%, -10°C@80%, 60°C@60% | Safety Standard | Design refer to UL 1012, UL 1950, TUV EN60950 | EMC Standard | Design refer to EN55055 class B, EN61000-4-2,3,4,5, EN61000-3-2,3 | Connection | 5P/9.5mm pitch terminal block |
|
|
|
|