60W Single Output |
|
AP-60-5 |
|
AP-60-12 |
|
AP-60-15 |
|
AP-60-24 |
|
|
|
FEATURES |
|
Low-cost, high reliability |
|
High efficiency, low working temp. |
|
Built in EMI filter, low ripple noise |
|
Compact size, light weight |
|
100% full load burn-in test |
|
Short circuit/over load protection |
|
Type No | Output | Tol. | R & N | Effi. | CK-60-5 | 5V, 12A | ±2 | 120mV | 73% | CK-60-12 | 12V, 5A | ±1 | 120mV | 76% | CK-60-15 | 15V, 4A | ±1 | 150mV | 77% | CK-60-24 | 24V, 2.5A | ±1 | 150mV | 79% | Input voltage | 85~264 full range | Input frequency | 47~63Hz | Inrush current | Cold start, 25A/115V, 50A/230V | Output voltage | Refer to above (±10% ADJ.) | Over voltage protection | 115% ~ 135% output voltage | Overload protection | 105% ~ 150% output pulsing mode | Setup, rise, hold up time | 800ms, 50ms, 10ms/115VAC | | 300ms, 50ms, 80ms/230VAC | Withstand voltage | I/P-O/P: 3KV, 1/P-FG: 1.5KV, 1 min. | Working temp | 0~50°C@100%, -10°C@80%, 60°C@60% | Safety Standard | Design refer to UL 1012, Ul 1950, TUV EN60950 | EMC Standard | Design refer to EN55022 class B, EN61000-4-2,3,4,5, EN60555-2,3 | Connection | 5P/9.5mm pitch terminal block |
|
|
|
|